Menu
support_agent Client Services

Support &
Resources.

KLIMARC's commitment to post-installation excellence. Access comprehensive technical documentation, submit service requests, and troubleshoot with our engineered solutions.

architecture System Blueprint
schema Schematic View
SCALE 1:50
REV B.4
description Product Catalogue

KLIMARC
AHU Series

picture_as_pdf
PDF Download
Verified Documentation
engineering Specs
Technical Specs
check
Updated 2026

Technical Documentation

Official catalogs, manuals, and specification sheets for KLIMARC systems.

menu_book
menu_book

KLIMARC Product Catalogue

Comprehensive overview of our industrial HVAC product line including AHUs, FAHUs, Ecology Units, and Fan Coil Units.

mode_fan
mode_fan

Fan Coil Units Catalogue

Detailed specifications and capacities for KLIMARC FCUs.

water_drop
water_drop

Condensate Hoods

Specifications for KVENT condensate hoods.

sensors
sensors

DCKV Hoods

Demand Control Kitchen Ventilation specifications.

filter_alt
filter_alt

Standard Baffle Hoods

Standard baffle filter kitchen hood specifications.

light_mode
light_mode

UV Kitchen Hoods

Advanced UV grease destruction hood specifications.

shower
shower

Water Mist Hoods

Cold water mist fire suppression hood specifications.

Troubleshooting Guide

Common operational anomalies and recommended engineering interventions.

air

Air Handling Units (KLIMARC)

Check and replace clogged air filters. Inspect fan blades, motor belts, and ensure dampers are not blocked. Verify VFD (Variable Frequency Drive) settings if applicable.
Clear clogged condensate drain lines. Ensure the unit is properly leveled and the drain trap is correctly dimensioned to overcome negative pressure.
Inspect the rotor and blower wheel for imbalance or damage. Check for worn bearings, loose mounting hardware, or frayed belts.
local_fire_department

Ecology Units & Kitchen Hoods (KVENT)

Inspect baffle or grease filters for severe clogging. Clean or replace immediately. Check for broken fan belts or duct obstructions. Verify the exhaust fan motor is running in the correct rotation direction.
Carbon media filters may be saturated and require replacement. Ensure all pre-filters are properly seated so grease does not bypass the filtration stages.
Ensure exhaust fans are operating correctly to remove heat. Check if cooking equipment was left on without the exhaust fan running. Clean heat links of excess grease buildup.
electric_bolt

General Electrical & Control

The motor's thermal overload protection is tripping. Check for blocked airflow causing overheating, verify correct voltage supply, and ensure the motor amperage does not exceed Full Load Amps (FLA).
Verify the main service disconnect and wall switches are ON. Check the breaker panel for tripped circuits. For 3-phase systems, ensure there is no phase loss from the utility provider.